Media 000704388: Whole Body [Ct]
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000704388: Whole Body [Ct]
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000704388
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Sorex fumeus
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Priscila Rothier
Date created
April 30, 2024
Date uploaded
January 27, 2025
FILE OBJECT DETAILS Field Definitions
File name
CUMV_20990_Sorex_fumeus.zip
File format(s)
ZIP archive, TIFF
File size
552 MB
Image width
872
Image height
548
Color space
BlackIsZero
Color depth
8
Compression
Uncompressed
X pixel spacing
0.036623
Y pixel spacing
0.036623
Z pixel spacing
0.036623
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,827
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225, Center for Nanoscale Systems (Harvard University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
National Science Foundation and the Ranges Digitization Network DBI-2228385
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
CUMV:Mamm:20990
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Center for Nanoscale Systems (Harvard University)
Creator
Priscila Rothier
Event date
April 30, 2024
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
1000
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
60
Power
--
Amperage
60
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000704388: Whole Body [Ct] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None