Media 000000545: Astragalus [Mesh] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
2 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000000545
Media type
Mesh
Object element or part
astragalus
Side
Right
Orientation
--
Short description
Smoothed surface file
Full description
Migrated MorphoSource 1 Media File Title: Smoothed surface file Migrated MorphoSource 1 Media Group Title: Smoothed surface file
Creator
--
Date created
--
Date uploaded
July 06, 2013
FILE OBJECT DETAILS
File format(s)
application/ply
File size
6.71 MB
Points
100,009
Polygons
199,978
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
3.307, 2.328, 4.160
Centroid coordinates
1.613, 2.503, 2.297
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x, AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1317525 to DMB & ERS
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
External identifier
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
irsnb:m:1235
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x
Device facility
AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
Creator
James Thostenson
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
na
Voltage
85
Power
0.0
Amperage
100
Surrounding material
none
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000000546: Astragalus [CTImageSeries] [CT]
.
Processing Details
Creator
James Thostenson
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000000546: Astragalus [CTImageSeries] [CT]
was processed
to create
derived
Media 000000545: Astragalus [Mesh] [CT]
(this media).
Processing Details
Creator
James Thostenson
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000000545: Astragalus [Mesh] [CT] (this media)