Media 000030478: Calcaneus [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000030478
Media type
Mesh
Object element or part
Calcaneus
Side
Right
Orientation
--
Short description
Raw Surface Mesh
Full description
Migrated MorphoSource 1 Media File Title: Raw Surface Mesh Migrated MorphoSource 1 Media Group Title: microCT Volume and Derivative Mesh Files Migrated MorphoSource 1 Media File Description: Scanner reverses side Migrated MorphoSource 1 Media Group Description: Scanner reverses side
Creator
--
Date created
--
Date uploaded
August 07, 2017

FILE OBJECT DETAILS

File format(s)
application/ply
File size
159 MB
Points
2,089,596
Polygons
4,179,354
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
7.657, 9.192, 22.006
Centroid coordinates
4.348, 5.035, 12.021
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
--
IP holder
Smithsonian, National Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these data , the collection of which was funded by NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object usnm:mammals:83652 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Justin Gladman, Mackenzie Aguilar
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
3142
Voltage
150
Power
0.02475
Amperage
165
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000030477: Calcaneus [CTImageSeries] [Etc] .

Processing Details

Creator
Justin Gladman, Mackenzie Aguilar
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000030477: Calcaneus [CTImageSeries] [Etc] was processed to create derived Media 000030478: Calcaneus [Mesh] [Etc] (this media).

Processing Details

Creator
Justin Gladman, Mackenzie Aguilar
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000030478: Calcaneus [Mesh] [Etc] (this media)