Media 000635978: Foot Elements
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000635978: Foot Elements
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000635978
Media type
Volumetric Image Series
Object element or part
foot elements
Object represented
Object taxonomy
Mammuthus columbi
Object organization
Side
--
Orientation
--
Short description
HRXCT scan - magnum
Full description
University of Texas High-Resolution X-ray CT Facility Archive
Rowe:
ANSP14360_magnum: Scan of Mammuthus columbi foot elements (magnum; ANSP 14360; Blackwarter Draw, Clovis, Roosevelt Co., NM) for Timothy Rowe of The University of Texas at Austin. Specimen scanned by David Edey on 13 August 2018.
16bitTIFF: Scan parameters: NSI scanner. Fein Focus High Power source, 210 kV, 0.165 mA, aluminum filter, Perkin Elmer detector, 0.25 pF gain, 1 fps, 1x1 binning, no flip, source to object 507.163 mm, source to detector 1316.679 mm, non-continuous CT scan, 2 frames averaged, 0 skip frames, 2700 projections, 3 gain calibrations, 15 mm calibration phantom, data range [-0.5, 10.0] (grayscale adjusted from NSI defaults), beam-hardening correction = 0.2. Voxel size = 94.4 μm. Total slices = 1838.
Creator
David Edey
Date created
August 13, 2018
Date uploaded
June 08, 2024
FILE OBJECT DETAILS Field Definitions
File name
16bitTIFF.zip
File format(s)
ZIP archive, TIFF
File size
7.45 GB
Image width
1721
Image height
1473
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.094400
Y pixel spacing
0.094400
Z pixel spacing
0.094400
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,838
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Academy of Natural Sciences of Drexel University
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
Data acquired for Tim Rowe. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ansp:vp:14360
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000635978: Foot Elements [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000635978: Foot Elements [CTImageSeries] [CT] (this media)