Media 000001975: Calcaneus [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000001975
Media type
Mesh
File format(s)
application/ply
File size
63,229,284 bytes
Object element or part
Calcaneus
Side
Right
Orientation
--
Short description
Raw surface file
Full description
Migrated MorphoSource 1 Media File Title: Raw surface file Migrated MorphoSource 1 Media Group Title: Raw surface file Migrated MorphoSource 1 Media File Description: raw surface Migrated MorphoSource 1 Media Group Description: raw surface
Creator
--
Date created
--
Date uploaded
January 14, 2014
Points
901,317
Polygons
1,802,812
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
4.5, 2.88, 7.5
Centroid coordinates
2.715, 2.277, 4.988
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40, Stony Brook University Center for Biotechnology (Stony Brook University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
Doug Boyer
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1317525 to DMB and ERS
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: D.M. Boyer provided access to these dataoriginally appearing in Boyer et al. (2013) NSF BCS 1317525 to DMB and ERS. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object gu:709 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40
Device facility
Stony Brook University Center for Biotechnology (Stony Brook University)
Creator
Doug Boyer
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
1
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000001977: Calcaneus [CTImageSeries] [Etc] .

Processing Details

Creator
Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000001977: Calcaneus [CTImageSeries] [Etc] was processed to create derived Media 000001975: Calcaneus [Mesh] [Etc] (this media).

Processing Details

Creator
Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000001975: Calcaneus [Mesh] [Etc] (this media)