Media 000020608: Rostrum
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000020608
Media type
Mesh
Object element or part
Rostrum
Object represented
Object taxonomy
Wannia scurriensis
Side
--
Orientation
--
Short description
Wannia scurriensis rostrum endocast STL
Full description
Migrated MorphoSource 1 Media File Title: Wannia scurriensis rostrum endocast STL Migrated MorphoSource 1 Media Group Title: CT data for Wannia scurriensis
Creator
--
Date created
--
Date uploaded
December 14, 2016

FILE OBJECT DETAILS Field Definitions

File name
Wannia-scurriensis-rostrum.stl
File format(s)
STL
File size
161 MB
Points
1684217
Polygons
3367254
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
151.112, 257.400, 84.958
Centroid coordinates
93.716, 156.387, 97.266
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tmm:539 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert, Jessie Maisano
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
350
Power
--
Amperage
4.2
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000020605: Braincase [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Matthew Colbert, Jessie Maisano
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000020605: Braincase [CTImageSeries] [Etc] was processed to create derived Media 000020608: Rostrum [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert, Jessie Maisano
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000020608: Rostrum [Mesh] [Etc] (this media)