Media 000034521: Weberian Apparatus [Video] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
6 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000034521
Media type
Video
Object element or part
Weberian Apparatus
Side
--
Orientation
--
Short description
Weberian Apparatus yaw animation
Full description
Migrated MorphoSource 1 Media File Title: Weberian Apparatus yaw animation Migrated MorphoSource 1 Media Group Title: Satan eurystomus Migrated MorphoSource 1 Media File Description: Weberian Apparatus yaw animation. Animation begins in left lateral view with the anterior margin facing to the left.
Creator
--
Date created
--
Date uploaded
October 24, 2017
FILE OBJECT DETAILS
File format(s)
video/quicktime
File size
16.3 MB
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
--
IP holder
Academy of Natural Sciences of Drexel University
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
tcwc:ichthyology:8279.01
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
60
Power
--
Amperage
110
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000030917: Element Unspecified [CTImageSeries] [Etc]
.
Processing Details
Creator
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000030917: Element Unspecified [CTImageSeries] [Etc]
was processed
to create
derived
Media 000034521: Weberian Apparatus [Video] [CT]
(this media).
Processing Details
Creator
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000034521: Weberian Apparatus [Video] [CT] (this media)