Media 000036092: Ct Scan Of Skull [Mesh] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
4 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000036092
Media type
Mesh
Object element or part
CT Scan of skull
Side
--
Orientation
--
Short description
STL of Atlas
Full description
Migrated MorphoSource 1 Media File Title: STL of Atlas Migrated MorphoSource 1 Media Group Title: CT scan of UF126295, Lyriocephalus scutatus
Creator
--
Date created
--
Date uploaded
November 04, 2017
FILE OBJECT DETAILS
File format(s)
application/stl
File size
6.18 MB
Points
64,096
Polygons
129,624
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
4.074, 4.980, 4.740
Centroid coordinates
9.063, 0.232, -12.995
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert Thematic Collections Network (TCN), NSF DBI-1701714
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
uf:herp:126295
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Ed Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
2200
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000036094: 16 Bit Tiffs [CTImageSeries] [Etc]
.
Processing Details
Creator
Ed Stanley
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000036094: 16 Bit Tiffs [CTImageSeries] [Etc]
was processed
to create
derived
Media 000036092: Ct Scan Of Skull [Mesh] [Etc]
(this media).
Processing Details
Creator
Ed Stanley
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000036092: Ct Scan Of Skull [Mesh] [Etc] (this media)