Media 000036113: Skull
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000036113
Media type
Mesh
Object element or part
Skull
Object represented
Object taxonomy
Draco dussumieri
Side
--
Orientation
--
Short description
STL of skull
Full description
Migrated MorphoSource 1 Media File Title: STL of skull Migrated MorphoSource 1 Media Group Title: CT scan of UF19920, Draco dussumieri
Creator
--
Date created
--
Date uploaded
November 05, 2017

FILE OBJECT DETAILS Field Definitions

File name
UF19920-Skull.stl
File format(s)
STL
File size
108 MB
Points
1124688
Polygons
2261948
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
12.998, 8.572, 6.896
Centroid coordinates
-0.653, 0.053, -3.208
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert Thematic Collections Network (TCN), NSF DBI-1701714
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Herp:19920 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Ed Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1900
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000036112: 16bit Tiffs [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Ed Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000036112: 16bit Tiffs [CTImageSeries] [Etc] was processed to create derived Media 000036113: Skull [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Ed Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000036113: Skull [Mesh] [Etc] (this media)