Media 000411939: Hamate
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000411939: Hamate
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS
Media ID
000411939
Media type
Mesh
Object element or part
Hamate
Object represented
Object taxonomy
Lemur catta
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Olivia Di Iorio
Date created
November 19, 2021
Date uploaded
January 09, 2022
FILE OBJECT DETAILS
File format(s)
application/stl
File size
16.7 MB
Points
32601
Polygons
64840
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
5.155, 7.256, 8.040
Centroid coordinates
-3.863, 4.448, 4.560
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(2 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Duke Lemur Center
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
dlc:6276f
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Gabriel Yapuncich, Darbi Griffith
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
135
Power
0.045090000000000005
Amperage
334
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000036793: Hands [CTImageSeries] [Etc].
Processing Details
Creator
Gabriel Yapuncich, Darbi Griffith
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000036793: Hands [CTImageSeries] [Etc]
was processed
with 2 activities
to create
derived
Media 000411939: Hamate [Mesh] [CT] (this media).
Processing Details
Creator
Olivia Di Iorio
Date processed
November 19, 2021
Software
Geomagic
Description
--
Description attachment
None
Processing Activity 1: Reconstructed Tomography to Mesh
Software
Avizo
Description
Processing Activity 2: Smoothing/Noise Reduction
Software
Geomagic
Description