Media 000042932: 3 D Mesh (Ply) [Mesh] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
8 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000042932
Media type
Mesh
Object element or part
3D Mesh (PLY)
Side
Right
Orientation
--
Short description
Right Splenial
Full description
Migrated MorphoSource 1 Media File Title: Right Splenial Migrated MorphoSource 1 Media Group Title: microCT volume files and mesh files Migrated MorphoSource 1 Media Group Description: Please additionally acknowledge Anne Schulp and Herman Voogd (Teylers Museum) for access to sepcimen and CT scanning permission
Creator
--
Date created
--
Date uploaded
March 04, 2018
FILE OBJECT DETAILS
File format(s)
application/ply
File size
2.6 MB
Points
62,030
Polygons
123,936
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
10133.268, 20205.182, 8704.635
Centroid coordinates
20958.199, 40836.136, 10953.057
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
Serjoscha W. Evers
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NERC studentship to SWE on the DTP Environmental Research (NE/L0021612/1)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Serjoscha W. Evers provided access to these dataoriginally appearing in Evers & Benson (2018) , the collection of which was funded by a NERC studentship to SWE on the DTP Environmental Research (NE/L0021612/1). The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
tm:4023
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
1
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
160
Power
--
Amperage
188
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000042922: Tiff Stack [CTImageSeries] [Etc]
.
Processing Details
Creator
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000042922: Tiff Stack [CTImageSeries] [Etc]
was processed
to create
derived
Media 000042932: 3 D Mesh (Ply) [Mesh] [Etc]
(this media).
Processing Details
Creator
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000042932: 3 D Mesh (Ply) [Mesh] [Etc] (this media)