Media 000420562: Endosseous Labyrinth [Mesh] [CT]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000420562
Media type
Mesh
Object element or part
Endosseous labyrinth
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
Catherine Johnson
Date created
February 09, 2022
Date uploaded
February 09, 2022

FILE OBJECT DETAILS

File format(s)
application/ply
File size
1.04 MB
Points
16,363
Polygons
32,758
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
2.291, 3.964, 3.986
Centroid coordinates
22.638, 30.585, 12.275
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Computed Tomography in Earth & Environmental Sciences (CTEES) (University of Michigan)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
University of Michigan Museum of Zoology (Copyright and License)
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
The European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson
Publisher
--
Cite as
Serjoscha Evers provided access to these data, originally appearing in "Evers et al. 2022. Independent origin of large labyrinth size in turtles", the collection of which was funded by the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ummz:mammals:156354 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Computed Tomography in Earth & Environmental Sciences (CTEES) (University of Michigan)
Creator
Roger Benson
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.25
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
110
Power
--
Amperage
135
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000068206: Whole Body [CTImageSeries] [CT] .

Processing Details

Creator
Roger Benson
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000068206: Whole Body [CTImageSeries] [CT] was processed to create derived Media 000420562: Endosseous Labyrinth [Mesh] [CT] (this media).

Processing Details

Creator
Catherine Johnson
Date processed
--
Software
Avizo
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000420562: Endosseous Labyrinth [Mesh] [CT] (this media)