Media 000080127: Tiff Stack
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000080127
Media type
Volumetric Image Series
Object element or part
Tiff stack
Object represented
Object taxonomy
Bonanzacarpum sprungerorum
Side
--
Orientation
--
Short description
Tiff stack
Full description
Migrated MorphoSource 1 Media File Title: Tiff stack Migrated MorphoSource 1 Media Group Title: Bonanzacarpum fruit
Creator
--
Date created
--
Date uploaded
June 11, 2019

FILE OBJECT DETAILS Field Definitions

File name
tif-stack-201240.zip
File format(s)
ZIP archive, TIFF
File size
492 MB
Image width
1106
Image height
227
Color space
BlackIsZero
Color depth
16
Compression
LZW
X pixel spacing
0.031080
Y pixel spacing
0.031080
Z pixel spacing
0.031080
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,070

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
University of California Regents; University of California Museum of Paleontology
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UCMP:P:201240 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Gary Scheiffele
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
500.093
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
2250
Voltage
200
Power
--
Amperage
140
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000080127: Tiff Stack [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Gary Scheiffele
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000080127: Tiff Stack [CTImageSeries] [CT] (this media)