Media 000081995: Whole Cleared And Stained Specimen
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000081995: Whole Cleared And Stained Specimen
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000081995
Media type
Volumetric Image Series
Object element or part
Whole cleared and stained specimen
Object represented
Object taxonomy
Calyptommatus leiolepis
Object organization
Side
--
Orientation
--
Short description
Zipped Tomogram stack (16bit tiffs)
Full description
Migrated MorphoSource 1 Media File Title: Zipped Tomogram stack (16bit tiffs) Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
June 25, 2019
FILE OBJECT DETAILS Field Definitions
File name
FML-30530.zip
File format(s)
ZIP archive, TIFF
File size
3.84 GB
Image width
852
Image height
838
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.017425
Y pixel spacing
0.017425
Z pixel spacing
0.017425
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
3,847
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x, AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
fml:h:30530
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x
Device facility
AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1500
Voltage
150
Power
0.028
Amperage
140
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000081995: Whole Cleared And Stained Specimen [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000081995: Whole Cleared And Stained Specimen [CTImageSeries] [Etc] (this media)