Media 000005160: Element Unspecified
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000005160
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Plecturocebus moloch
Object organization
Side
Unknown
Orientation
--
Short description
MCZ 26922 skull
Full description
Migrated MorphoSource 1 Media File Title: MCZ 26922 skull Migrated MorphoSource 1 Media Group Title: MCZ 26922 skull Migrated MorphoSource 1 Media File Description: scanned as 26921, but the specimen number is 26922. Migrated MorphoSource 1 Media Group Description: scanned as 26921, but the specimen number is 26922.
Creator
--
Date created
--
Date uploaded
March 09, 2015

FILE OBJECT DETAILS Field Definitions

File name
Callicebus_26921.zip
File format(s)
ZIP archive, DICOM
File size
2.55 GB
Image width
924
Image height
1319
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.047097
Y pixel spacing
0.047097
Z pixel spacing
0.047097
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,358

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225, Center for Nanoscale Systems (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
originally appearing in
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:Mamm:26922 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225
Device facility
Center for Nanoscale Systems (Harvard University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
1050
Voltage
80
Power
0.0096
Amperage
120
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000005160: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000005160: Element Unspecified [CTImageSeries] [Etc] (this media)