Media 000012866: Cranium
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000012866
Media type
Volumetric Image Series
Object element or part
Cranium
Object represented
Object taxonomy
Daubentonia madagascariensis
Object organization
Side
Midline
Orientation
--
Short description
Zipped Tiff Stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped Tiff Stack Migrated MorphoSource 1 Media Group Title: Zipped Tiff Stack
Creator
--
Date created
--
Date uploaded
May 23, 2016

FILE OBJECT DETAILS Field Definitions

File name
Gonzales_Daubentonia_USNM_305066_skull.zip
File format(s)
ZIP archive, TIFF
File size
3.93 GB
Image width
1413
Image height
1772
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.050931
Y pixel spacing
0.050931
Z pixel spacing
0.050931
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,863

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object USNM:MAMM:USNM 305066 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer, Miles Schaeffer
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
1800
Voltage
130
Power
0.0169
Amperage
130
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000012866: Cranium [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Doug Boyer, Miles Schaeffer
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000012866: Cranium [CTImageSeries] [Etc] (this media)