Media 000344884: Calcaneus
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000344884: Calcaneus
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000344884
Media type
Mesh
Object element or part
Calcaneus
Object represented
Object taxonomy
Perodicticus potto
Object organization
Side
Right
Orientation
--
Short description
Smooth surface file
Full description
--
Creator
--
Date created
--
Date uploaded
February 15, 2021
FILE OBJECT DETAILS Field Definitions
File name
DLC919m_Perodicticus_potto_R_calc.ply
File format(s)
PLY
File size
19.6 MB
Points
276830
Polygons
553644
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
8.271, 9.631, 12.521
Centroid coordinates
9.785, 4.993, 7.493
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(1 step)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Duke Lemur Center
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
dlc:919m
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Gabriel Yapuncich
Event date
February 14, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
1800
Voltage
155
Power
0.018
Amperage
120
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000015692: Foot [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Gabriel Yapuncich
Event date
February 14, 2021
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000015692: Foot [CTImageSeries] [CT]
was processed
with 1 activity
to create
derived
Media 000344884: Calcaneus [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Gabriel Yapuncich
Event date
February 15, 2021
Software
Avizo 2019.3
Description
--
Description attachment
None
Processing Activity 1: Reconstructed Tomography to Mesh
Software
Avizo 2019.3
Description
Media produced by this event on MorphoSource