Media 000023926: Element Unspecified [Mesh] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000023926
Media type
Mesh
Object element or part
--
Side
--
Orientation
--
Short description
DPC-26292, Masradapis tahai
Full description
Migrated MorphoSource 1 Media File Title: DPC-26292, Masradapis tahai Migrated MorphoSource 1 Media Group Title: ply surface Migrated MorphoSource 1 Media File Description: chiral-correct surface file
Creator
--
Date created
--
Date uploaded
March 04, 2017
FILE OBJECT DETAILS
File format(s)
application/ply
File size
54.2 MB
Points
750,461
Polygons
1,499,858
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
10.543, 7.655, 14.387
Centroid coordinates
8.480, 4.774, 10.833
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
Duke Lemur Center
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1231288 (to E.R. Seiffert, G. F. Gunnell, D. M. Boyer, and J. G. Fleagle) and NSF DBI 1458192 (to G. F. Gunnell, R. F. Kay and D. M. Boyer)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Gregg Gunnell provided access to these dataoriginally appearing in Seiffert et al. (2017) , the collection of which was funded by NSF BCS 1231288 and NSF DBI 1458192. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
dpc:26292
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Erik Seiffert
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000023926: Element Unspecified [Mesh] [Etc]
(this media).
Processing Details
Creator
Erik Seiffert
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000023926: Element Unspecified [Mesh] [Etc] (this media)