Media 000036780: Element Unspecified
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

Media preview currently unavailable. Please check back later.

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000036780
Media type
Mesh
Object element or part
--
Object represented
Object taxonomy
Eonycteris spelaea glandifera
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: cranium
Creator
--
Date created
--
Date uploaded
November 07, 2017

FILE OBJECT DETAILS Field Definitions

File name
Eonycteris_spelaea_156952_cranium.ply
File format(s)
PLY
File size
755 MB
Points
9940284
Polygons
19910811
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
18.730, 33.150, 14.180
Centroid coordinates
26.068, 21.306, 85.719
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 100, University of Michigan School of Dentistry MicroCT Core (University of Michigan)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Michigan Museum of Zoology (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DEB 1501304
Publisher
University of Michigan, Museum of Zoology, 3600 Varsity Drive, Ann Arbor, Michigan 48108
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UMMZ:mammals:156952 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 100
Device facility
University of Michigan School of Dentistry MicroCT Core (University of Michigan)
Creator
Michelle Lynch, Jeff Shi, Erin Westeen
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.25
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
750
Voltage
70
Power
0.007980000000000001
Amperage
114
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000036779: Cranium [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Michelle Lynch, Jeff Shi, Erin Westeen
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000036779: Cranium [CTImageSeries] [CT] was processed to create derived Media 000036780: Element Unspecified [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Michelle Lynch, Jeff Shi, Erin Westeen
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000036780: Element Unspecified [Mesh] [Etc] (this media)