Media 000354524: Partial Cranium
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000354524
Media type
Volumetric Image Series
Object element or part
Partial cranium
Object represented
Object taxonomy
Toxochelys latiremis
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
April 01, 2021

FILE OBJECT DETAILS Field Definitions

File name
Toxochelys_latiremus_AMNH_FR1042.zip
File format(s)
ZIP archive, TIFF
File size
130 MB
Image width
1010
Image height
659
Color space
BlackIsZero
Color depth
8
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.056489
Y pixel spacing
0.056489
Z pixel spacing
0.056489
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,852

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x, AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
American Museum of Natural History
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
NERC studentship to Serjoscha Evers on the DTP Environmental Research (NE/L0021612/1)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:farb:1042 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x
Device facility
AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
Creator
Hongyu, Yi
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
333 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
170 kV
Power
--
Amperage
180 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000354524: Partial Cranium [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Hongyu, Yi
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000354524: Partial Cranium [CTImageSeries] [CT] (this media)