Media 000354567: Whole Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000354567
Media type
Volumetric Image Series
Object element or part
Whole body
Object represented
Object taxonomy
Hemicordylus capensis
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
April 01, 2021

FILE OBJECT DETAILS Field Definitions

File name
AMNH-H-175083.zip
File format(s)
ZIP archive, TIFF
File size
205 MB
Image width
887
Image height
465
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.070533
Y pixel spacing
0.070533
Z pixel spacing
0.070533
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,671

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x, AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object AMNH:Herpetology:R-175083 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x
Device facility
AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
Creator
Edward Stanley
Event date
--
Software
Phoenix Datos|X
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.333096
Flux normalization
Yes
Pixel spacing calibration
Geometry
Shading correction
Yes
Frame averaging
3
Projections
1450
Voltage
180
Power
120
Amperage
21.6
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
--
Detector pixels X
1024
Detector pixels size X
--
Detector pixels Y
1024
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
Tungston
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000354567: Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
April 01, 2021
Software
Datos|xR
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000354567: Whole Body [CTImageSeries] [CT] (this media)