Media 000015362: Foot [Image] [Etc]
Represents:
Biological Specimen
In Collection

FILE OBJECT DETAILS

Media ID
000015362
Media type
Image
File format(s)
image/jpeg
File size
191,212 bytes
Object element or part
Foot
Side
--
Orientation
--
Short description
Foot Preview of Volume Rendering
Full description
Migrated MorphoSource 1 Media File Title: Foot Preview of Volume Rendering Migrated MorphoSource 1 Media Group Title: Zipped Tiff Stack
Creator
--
Date created
--
Date uploaded
August 03, 2016
Image width
1447
Image height
1013
Color space
YCbCr
Color depth
8/8/8
Compression
JPEG
X pixel spacing
0.0182315
Y pixel spacing
0.0182315
Z pixel spacing
0.0182315
Pixel spacing units
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
Duke Lemur Center
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1540421
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: The Duke Lemur Center provided access to these data, originally appearing in Yapuncich et al. (2019), the collection of which was funded by NSF BCS 1540421 to Gabriel S. Yapuncich and Doug M. Boyer. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dlc:656m was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Gabriel Yapuncich, Darbi Griffith
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Filter
--
Frame averaging
1
Projections
2000
Voltage
155
Power
0.019
Amperage
120
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000015354: Foot [CTImageSeries] [Etc] .

Processing Details

Creator
Gabriel Yapuncich, Darbi Griffith
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000015354: Foot [CTImageSeries] [Etc] was processed to create derived Media 000015362: Foot [Image] [Etc] (this media).

Processing Details

Creator
Gabriel Yapuncich, Darbi Griffith
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000015362: Foot [Image] [Etc] (this media)