Media 000363743: Lacrimal
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000363743
Media type
Volumetric Image Series
Object element or part
lacrimal
Object represented
Object taxonomy
Majungasaurus crenatissimus
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
May 14, 2021

FILE OBJECT DETAILS Field Definitions

File name
FMNH_PR_2100_r_lacrimal.zip
File format(s)
ZIP archive, DICOM
File size
184 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.298828
Y pixel spacing
0.298828
Z pixel spacing
0.200000
Pixel spacing units
Mm
Slice thickness
0.625000
Number of images in set
939

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT, Stony Brook University Medical Center (Stony Brook University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF EAR_1525915; Ohio University Heritage College of Osteopathic Medicine; NSF EAR_1123642
Publisher
Patrick M. O'Connor; Joseph R. Groenke; Ohio University; Mahajanga Basin Project
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:PR:2100 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT
Device facility
Stony Brook University Medical Center (Stony Brook University)
Creator
Groenke, Joseph
Event date
March 20, 2012
Software
GE
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1825
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
541
Source detector distance
949.1
Target material
--
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Spiral

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000363743: Lacrimal [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Groenke, Joseph
Event date
February 25, 2021
Software
Avizo
Description
cropping of batch files and export as dicoms
Description attachment
None

Media produced by this event on MorphoSource

Media 000363743: Lacrimal [CTImageSeries] [CT] (this media)