Media 000373721: Cranium
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000373721
Media type
Mesh
Object element or part
Cranium
Object represented
Object taxonomy
Naomichelys speciosa
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Serjoscha Evers
Date created
August 02, 2021
Date uploaded
August 02, 2021

FILE OBJECT DETAILS Field Definitions

File name
Naomichelys_speciosa_FMNHPR273_Cranium.ply
File format(s)
PLY
File size
421 MB
Points
10118952
Polygons
20014782
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
89856.390, 125961.821, 61825.738
Centroid coordinates
54076.325, 76157.169, 33479.256
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x S240, Laboratory for Virtual Anthropology and Morphometrics (University of Tübingen)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:PR:273 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x S240
Device facility
Laboratory for Virtual Anthropology and Morphometrics (University of Tübingen)
Creator
Scherf, Heike
Event date
March 08, 2012
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
333 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
150 kV
Power
--
Amperage
170 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000355953: Cranium [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Scherf, Heike
Event date
March 08, 2012
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000355953: Cranium [CTImageSeries] [CT] was processed to create derived Media 000373721: Cranium [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Serjoscha Evers
Event date
--
Software
Mimics
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000373721: Cranium [Mesh] [CT] (this media)