Media 000113998: Turbinates [CTImageSeries] [CT]
Represents:
Biological Specimen

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000113998
Media type
CTImageSeries
File format(s)
image/tiff
File size
2,361,641,305 bytes
Object element or part
turbinates
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0121\\r\\n\\r\\nScanned images of skulls and turbinates of Canis latrans (coyote) for Blaire Van Valkenburg and Ari Pollack of UCLA. Scanning done by Richard Ketcham on 8/9-8/12/99. Samples mounted in plexiglass cylinders, held in place with foam or clay. Coarse (skull) and fine (turbinate) scans done on different systems, due to size and resolution considerations. Only 16-bit TIFF image files archived.\\r\\n\\r\\nCoyote/male: UCLA collection number 2739, collected by Ron Otuski in the Granite Mountains, San Bernardino County, California, April 1972.\\r\\nTurbinates: II, 180 kV, 0.133 mA, no filter, empty container wedge, 160% offset, slice thickness 5 lines/0.286 mm, S.O.D. 99 mm, 1200 views, 7 samples per view, inter-slice spacing 0.286 mm, field of reconstruction 36 mm, reconstruction offset 500, reconstruction scale 60. Reconstructed centered at position x=0.9 mm, y=6.2 mm, angle = -4.34 degrees. Scanned in 3-slice mode.\\r\\n
Creator
--
Date created
--
Date uploaded
April 01, 2020
Image width
1024
Image height
1024
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.035
Y pixel spacing
0.035
Z pixel spacing
0.286
Pixel spacing units
Mm
Number of images in set
1,625

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
University of California Los Angeles
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
IIS-9874781, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Blaire Van Valkenburgh provided access to these data , with data collection funded by NSF IIS-9874781 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UCLA:SO:2739 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Richard Ketcham
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
7
Projections
1200
Voltage
180
Power
--
Amperage
133
Surrounding material
empty container
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000113998: Turbinates [CTImageSeries] [CT] (this media).

Processing Details

Creator
Richard Ketcham
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000113998: Turbinates [CTImageSeries] [CT] (this media)