Media 000397517: Urohyal
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000397517
Media type
Mesh
Object element or part
Urohyal
Object represented
Object taxonomy
Cladarosymblema sp.
Side
Midline
Orientation
--
Short description
--
Full description
--
Creator
Alice Clement
Date created
November 21, 2021
Date uploaded
November 22, 2021

FILE OBJECT DETAILS Field Definitions

File name
Cladarosymblema_Urohyal.stl
File format(s)
STL
File size
7.27 MB
Points
74721
Polygons
152558
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
0.941, 4.271, 0.885
Centroid coordinates
87.699, 53.704, 26.420
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Medical Device Research Institute (Flinders University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Queensland Museum (Copyright and License)
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On Any Repository
Funding attribution
Queensland Museum
Publisher
Queensland Museum
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object QM:F:21082 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Medical Device Research Institute (Flinders University)
Creator
Egon Perilli
Event date
--
Software
CT Pro 3D
Description
The holotype (QMF 21082) was scanned at the Flinders University CT Lab by Egon Perilli for Alice Clement and John Long using a Nikon XTH225 using the following parameters: 160 kV; 282 µA; 0.25 mm tin filter; 2.83 s exposure; and with a resulting voxel size of 58µm.
Description attachment
None
Reference attachment
None
Exposure time
2.83 s
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
160 kV
Power
282 uA
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Processing Details Field Definitions

Creator
Egon Perilli
Event date
--
Software
VG StudioMax
Description
--
Description attachment
None

STEP 3: IMAGE PROCESSING

Derived Media 000383362: Anterior Part Of A Fish Including The Skull, Pectoral Fins And Part Of The Scale Covered Trunk [CTImageSeries] [CT] was processed to create derived Media 000397517: Urohyal [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Alice Clement
Event date
--
Software
Mimics
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000397517: Urohyal [Mesh] [CT] (this media)