Media 000397324: Dome
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000397324
Media type
Volumetric Image Series
Object element or part
dome
Object represented
Object taxonomy
Stegoceras sp.
Side
--
Orientation
--
Short description
--
Full description
University of Texas High-Resolution X-ray CT Facility Archive Goodwin: UCMP130051hires: Scans of a pachycephalosaur dome (UCMP 130051; Judith River Fm., Campanian, Hill Co., Montana) for Mark Goodwin of the University of California at Berkeley. Specimen scanned by Matthew Colbert 16 October 2015. 16bit: Scan parameters: NSI scanner. GE Titan source, small spot, 450 kV, 0.5 mA, 2 brass filters, Perkin Elmer detector, 0.5 pF gain, 1 fps (999.911 ms integration time), no binning, no flip, source to object 759 mm, source to detector 1486.209 mm, continuous CT scan, no frames averaged, 0 skip frames, 2088 projections, 4 gain calibrations, 15 mm calibration phantom, data range [-4, 22.5] (rescaled from NSI default). Voxel size = 0.1034 mm, beam-hardening correction = 0.4. Total slices = 1875.
Creator
Matthew Colbert
Date created
October 16, 2015
Date uploaded
November 19, 2021

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
4.04 GB
Image width
1276
Image height
1088
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.103400
Y pixel spacing
0.103400
Z pixel spacing
0.103400
Pixel spacing units
--
Slice thickness
--
Number of images in set
1,875

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
University of California Museum of Paleontology; University of California Regents
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF EAR-1053370, the Doris O. and Samuel P. Welles Research Fund, and NSF DBI-1902242
Publisher
oUTCT PEN
Cite as
oUTCT provided access to these data, originally appearing in ?, with data collection funded by NSF EAR-1053370 and the Doris O. and Samuel P. Welles Research Fund and data upload to MorphoSource funded by DBI-1902242.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UCMP:V:130051 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
October 16, 2015
Software
--
Description
University of Texas High-Resolution X-ray CT Facility Archive Goodwin: UCMP130051hires: Scans of a pachycephalosaur dome (UCMP 130051; Judith River Fm., Campanian, Hill Co., Montana) for Mark Goodwin of the University of California at Berkeley. Specimen scanned by Matthew Colbert 16 October 2015. 16bit: Scan parameters: NSI scanner. GE Titan source, small spot, 450 kV, 0.5 mA, 2 brass filters, Perkin Elmer detector, 0.5 pF gain, 1 fps (999.911 ms integration time), no binning, no flip, source to object 759 mm, source to detector 1486.209 mm, continuous CT scan, no frames averaged, 0 skip frames, 2088 projections, 4 gain calibrations, 15 mm calibration phantom, data range [-4, 22.5] (rescaled from NSI default). Voxel size = 0.1034 mm, beam-hardening correction = 0.4. Total slices = 1875.
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
2088
Voltage
450
Power
--
Amperage
0.5
Surrounding material
--
X-ray tube type
GE Titan
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000397324: Dome [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000397324: Dome [CTImageSeries] [CT] (this media)