Media 000414524: Mandible [Mesh] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000414524
Media type
Mesh
Object element or part
Mandible
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Jasper Ponstein
Date created
January 17, 2022
Date uploaded
January 17, 2022
FILE OBJECT DETAILS
File format(s)
application/ply
File size
6.78 MB
Points
99,395
Polygons
198,216
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
33.877, 37.006, 15.765
Centroid coordinates
9.959, 3.381, 13.255
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Yxlon FF35 CT, Museum für Naturkunde, Berlin (Museum für Naturkunde, Berlin)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
zmb:r:16196
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Yxlon FF35 CT
Device facility
Museum für Naturkunde, Berlin (Museum für Naturkunde, Berlin)
Creator
Jasper Ponstein
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
150 kV
Power
--
Amperage
140 uA
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000414521: Mandible [CTImageSeries] [CT]
.
Processing Details
Creator
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000414521: Mandible [CTImageSeries] [CT]
was processed
to create
derived
Media 000414524: Mandible [Mesh] [CT]
(this media).
Processing Details
Creator
Jasper Ponstein
Date processed
--
Software
VGStudio
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000414524: Mandible [Mesh] [CT] (this media)