Media 000452944: Partial Skull
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000452944
Media type
Volumetric Image Series
Object element or part
partial skull
Object represented
Object taxonomy
Diademodon tetragonus
Side
--
Orientation
--
Short description
HRXCT scan - partial skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0847 Rowe: Diademodon: Scans of the fossil skull of Diademodon cf. tetragonus (UCMP 42446; coll. by Charles Camp, 1948, South Africa, Early Triassic, Karoo Group, Cynognathus Zone) for Dr. Timothy Rowe of the Department of Geological Sciences, The University of Texas at Austin. Scanned by Matthew Colbert 18 February 2003. Software skipped slices 180, 210, 240, 241, 242, 243, 270, 300, 330, 360, and 390. These slices were regathered by Richard Ketcham. 16bitbh: 1024x1024 16-bit TIFF images. P250D, 420 kV, 4.8 mA, two brass filters, empty container wedge, 190% offset, integration time 64 ms, slice thickness 1 mm, S.O.D. 698 mm, 1000 views, one ray averaged per view, one sample per view, interslice spacing –0.8 mm, field of reconstruction 266 mm, reconstruction offset 3000, reconstruction scale 1600. Beam hardening correction (parameters: 0.0, 0.9, 0.05) applied to sinograms prior to reconstruction. Total slices = 410.
Creator
Matthew Colbert
Date created
February 18, 2003
Date uploaded
July 29, 2022

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
278 MB
Image width
1017
Image height
524
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.260000
Y pixel spacing
0.260000
Z pixel spacing
0.800000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
410

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
IP holder
University of California Regents; University of California Museum of Paleontology
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
oUTCT provided access to these data, funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UCMP:V:42446 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
February 18, 2003
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000452944: Partial Skull [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000452944: Partial Skull [CTImageSeries] [CT] (this media)