Media 000049204: Whole Alchohol Preserved Specimen [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000049204
Media type
CTImageSeries
File format(s)
image/tiff
File size
475,836,578 bytes
Object element or part
Whole alchohol preserved specimen
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: Whole alchohol preserved specimen
Creator
--
Date created
--
Date uploaded
May 28, 2018
Image width
411
Image height
360
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.103917
Y pixel spacing
0.103917
Z pixel spacing
0.103917
Pixel spacing units
Mm
Number of images in set
1,859

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Restricted Download
Download reviewer
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
IP holder(s) (Name, Type)
Name: Florida Museum of Natural History, University of Florida, Type:
Funding attribution
Overt DBI 1701714
Publisher
--
Cite as
--
Additial usage agreement
None
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uf:fish:5602 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zach Randall
Date
2021-04-28
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
3
Projections
600
Voltage
120
Power
0.026
Amperage
220
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000049204: Whole Alchohol Preserved Specimen [CTImageSeries] [CT] (this media).

Processing Details

Creator
Zach Randall
Date processed
2021-04-28
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000049204: Whole Alchohol Preserved Specimen [CTImageSeries] [CT] (this media)