Media 000044205: Element Unspecified [Mesh] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000044205
Media type
Mesh
Object element or part
--
Side
--
Orientation
--
Short description
W809 Baboon Skull ply
Full description
Migrated MorphoSource 1 Media File Title: W809 Baboon Skull ply Migrated MorphoSource 1 Media Group Title: W809 Baboon Skull
Creator
--
Date created
--
Date uploaded
March 22, 2018
FILE OBJECT DETAILS
File format(s)
application/ply
File size
114 MB
Points
1,466,964
Polygons
2,994,966
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
126.430, 126.579, 223.654
Centroid coordinates
1.655, -166.257, -151.909
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Biograph 40 TruePoint Tomograph, Center for Clinical Research (CCIR) (Washington University School of Medicine)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
snrpc:8860.W809
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Biograph 40 TruePoint Tomograph
Device facility
Center for Clinical Research (CCIR) (Washington University School of Medicine)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000044204: Element Unspecified [CTImageSeries] [Etc]
.
Processing Details
Creator
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000044204: Element Unspecified [CTImageSeries] [Etc]
was processed
to create
derived
Media 000044205: Element Unspecified [Mesh] [Etc]
(this media).
Processing Details
Creator
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000044205: Element Unspecified [Mesh] [Etc] (this media)