Media 000054783: Inner Ears [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000054783
Media type
CTImageSeries
Object element or part
Inner Ears
Side
Midline
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: Medical CT DICOM stack Migrated MorphoSource 1 Media Group Description: Scan of inner ear higher Z resolution (0.1 mm)
Creator
--
Date created
--
Date uploaded
July 20, 2018
FILE OBJECT DETAILS
File format(s)
application/dicom
File size
64.9 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.292969
Y pixel spacing
0.292969
Z pixel spacing
0.100000
Pixel spacing units
Mm
Slice thickness
0.4
Number of images in set
231
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Biograph 40 TruePoint Tomograph, Center for Clinical Research (CCIR) (Washington University School of Medicine)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
snrpc:8860.W809
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Biograph 40 TruePoint Tomograph
Device facility
Center for Clinical Research (CCIR) (Washington University School of Medicine)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000054783: Inner Ears [CTImageSeries] [Etc]
(this media).
Processing Details
Creator
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000054783: Inner Ears [CTImageSeries] [Etc] (this media)