Media 000045099: Element Unspecified
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000045099
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Papio sp.
Side
--
Orientation
--
Short description
Papio Skull DICOM Stack
Full description
Migrated MorphoSource 1 Media File Title: Papio Skull DICOM Stack Migrated MorphoSource 1 Media Group Title: Papio skull with manible and higher resolution (400um) scans of the inner ear
Creator
--
Date created
--
Date uploaded
April 04, 2018

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, DICOM
File size
91.1 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.292969
Y pixel spacing
0.292969
Z pixel spacing
0.600000
Pixel spacing units
Mm
Slice thickness
0.6
Number of images in set
323

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Biograph 40 TruePoint Tomograph, Center for Clinical Research (CCIR) (Washington University School of Medicine)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object snrpc:6335.W980 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Biograph 40 TruePoint Tomograph
Device facility
Center for Clinical Research (CCIR) (Washington University School of Medicine)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
120
Power
0.036
Amperage
304
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000045099: Element Unspecified [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000045099: Element Unspecified [CTImageSeries] [CT] (this media)