Media 000048004: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000048004
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Horabagrus brachysoma
Side
--
Orientation
--
Short description
Horabagrus brachysoma SAIAB fish 59825
Full description
Migrated MorphoSource 1 Media File Title: Horabagrus brachysoma SAIAB fish 59825 Migrated MorphoSource 1 Media Group Title: Horabagrus brachysoma SAIAB fish 59825
Creator
--
Date created
--
Date uploaded
May 04, 2018

FILE OBJECT DETAILS Field Definitions

File name
Horabagrus_brachysoma_8bitjpg.zip
File format(s)
ZIP archive, JPEG
File size
26.9 MB
Image width
1024
Image height
1024
Color space
YCbCr
Color depth
8
Compression
JPEG
X pixel spacing
0.073285
Y pixel spacing
0.073285
Z pixel spacing
0.157200
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
660

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
South African Institute for Aquatic Biodiversity
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object saiab:fish:59825 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
180
Power
--
Amperage
0.133
Surrounding material
empty container
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000048004: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000048004: Element Unspecified [CTImageSeries] [Etc] (this media)