Media 000362641: Skeleton
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000362641
Media type
Mesh
Object element or part
Skeleton
Object represented
Object taxonomy
Pantherophis guttatus
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
May 06, 2021

FILE OBJECT DETAILS Field Definitions

File name
LSUMZ_Herp_88802_Body.stl
File format(s)
STL
File size
171 MB
Points
1792156
Polygons
3585042
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
146.710, 73.214, 162.156
Centroid coordinates
-0.854, 5.868, 2.629
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1701714 ("oVert: TCN" parent grant)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object LSUMZ:Herps:88802 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zachary Randall
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.200098
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1800
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000073953: Whole Body [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Zachary Randall
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000073953: Whole Body [CTImageSeries] [Etc] was processed to create derived Media 000362641: Skeleton [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Jaimi Gray
Event date
May 06, 2021
Software
VG Studio Max
Description
Skeleton
Description attachment
None

Media produced by this event on MorphoSource

Media 000362641: Skeleton [Mesh] [CT] (this media)