Media 000098420: Head [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

GENERAL DETAILS

Media ID
000098420
Media type
CTImageSeries
Object element or part
head
Side
--
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
January 08, 2020

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
1.06 GB
Image width
1000
Image height
799
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.023255
Y pixel spacing
0.023255
Z pixel spacing
0.023255
Pixel spacing units
Mm
Number of images in set
1,877

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Open Download
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714; oVert TCN
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: University of Florida provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uf:fish:173080 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zachary Randall
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.200098
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1200
Voltage
100
Power
0.02
Amperage
200
Surrounding material
None
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000098420: Head [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Zachary Randall
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000098420: Head [CTImageSeries] [Etc] (this media)