Media 000079368: Body
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000079368
Media type
Volumetric Image Series
Object element or part
body
Object taxonomy
Rhinichthys evermanni
Side
--
Orientation
--
Short description
zipped jpg stack
Full description
Migrated MorphoSource 1 Media File Title: zipped jpg stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives Migrated MorphoSource 1 Media Group Description: Specimen Scan Symbol is L
Creator
--
Date created
--
Date uploaded
May 30, 2019

FILE OBJECT DETAILS Field Definitions

File name
Uwfc-A-020224_body.zip
File format(s)
ZIP archive, JPEG
File size
243 MB
Image width
639
Image height
1027
Color space
YCbCr
Color depth
8
Compression
JPEG
X pixel spacing
0.026072
Y pixel spacing
0.026072
Z pixel spacing
0.026072
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,931

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
University of Washington Fish Collection
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1701665; NSF DBI-1701714; oVert TCN
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: University of Washington Fish Collection provided access to these data provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UWFC:ADULT COLLECTION:UW 020224 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Matthew Kolmann
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1.06
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
4
Projections
600
Voltage
70
Power
0.007980000000000001
Amperage
114
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000079368: Body [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Kolmann
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000079368: Body [CTImageSeries] [Etc] (this media)