Media 000080654: Articulated First Three Caudal Vertebrae
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000080654
Media type
Volumetric Image Series
Object element or part
articulated first three caudal vertebrae
Object represented
Object taxonomy
Rahonavis ostromi
Side
Midline
Orientation
--
Short description
UA 8656 caudal vertebrae 1-3
Full description
Migrated MorphoSource 1 Media File Title: UA 8656 caudal vertebrae 1-3 Migrated MorphoSource 1 Media Group Title: micro-CT volume data and polygon derivatives
Creator
--
Date created
--
Date uploaded
June 14, 2019

FILE OBJECT DETAILS Field Definitions

File name
UA_8656_caudals_1-3-DICOM.zip
File format(s)
ZIP archive, DICOM
File size
108 MB
Image width
455
Image height
350
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.045000
Y pixel spacing
0.045000
Z pixel spacing
0.045000
Pixel spacing units
Mm
Slice thickness
0.044782000000000002
Number of images in set
543

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric eXplore Locus in vivo, Ohio University MicroCT Facility (Ohio University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
Patrick O'Connor
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF EAR-1123642
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Patrick O'Connor and colleagues provided access to these datapublished in conjunction with Forster et al. 2020. with funding from the National Science Foundation. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ua:8656 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric eXplore Locus in vivo
Device facility
Ohio University MicroCT Facility (Ohio University)
Creator
Patrick O'Connor
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.08
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
4
Projections
--
Voltage
80
Power
0.003984
Amperage
49.8
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000080654: Articulated First Three Caudal Vertebrae [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Patrick O'Connor
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000080654: Articulated First Three Caudal Vertebrae [CTImageSeries] [Etc] (this media)