Media 000363623: Quadrate
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000363623
Media type
Mesh
Object element or part
quadrate
Object represented
Object taxonomy
Majungasaurus crenatissimus
Side
Left
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
May 13, 2021

FILE OBJECT DETAILS Field Definitions

File name
FMNH_PR_2100_l_quadrate.ply
File format(s)
PLY
File size
35.7 MB
Points
507554
Polygons
1014213
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
63.215, 107.416, 179.237
Centroid coordinates
46.805, 13.278, 4.426
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT, Stony Brook University Medical Center (Stony Brook University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF EAR_1525915; Ohio University Heritage College of Osteopathic Medicine; NSF EAR_1123642
Publisher
Patrick M. O'Connor; Joseph R. Groenke; Ohio University; Mahajanga Basin Project
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:PR:2100 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT
Device facility
Stony Brook University Medical Center (Stony Brook University)
Creator
Groenke, Joseph
Event date
December 30, 2008
Software
GE
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1825
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
140
Power
--
Amperage
250
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
541
Source detector distance
949.1
Target material
--
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Spiral

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000363620: Quadrate [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Groenke, Joseph
Event date
February 25, 2021
Software
Avizo
Description
cropping from batch scans and export as dicoms
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000363620: Quadrate [CTImageSeries] [CT] was processed to create derived Media 000363623: Quadrate [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Acker, Alex
Event date
February 04, 2021
Software
Avizo
Description
export of ply format from isosurface rendering
Description attachment
None

Media produced by this event on MorphoSource

Media 000363623: Quadrate [Mesh] [CT] (this media)