Media 000433757: Dentary
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000433757
Media type
Mesh
Object element or part
Dentary
Object represented
Object taxonomy
Onchodactylus japonicus
Side
Left
Orientation
--
Short description
--
Full description
Segmented using Amira 6.7.0. Thresholding was used to determine the general boundary of the bone. Surface models were generated using Algorithim mode repeatable and Unconstrained smoothing set at 2. The thumbnail screenshot was taken in orthographic view.
Creator
Marc Jones
Date created
November 09, 2021
Date uploaded
April 04, 2022

FILE OBJECT DETAILS Field Definitions

File name
Onychodactylus_japonicus_OUMNH_6991__dentary_left_uncon2.ply
File format(s)
PLY
File size
30.1 MB
Points
420807
Polygons
841586
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
6.116, 3.290, 8.125
Centroid coordinates
7.833, 9.913, 5.705
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Oxford University Museum of Natural History (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object oumnh:6991 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)
Creator
Roger Benson, Tom Davies, Armin Schmitt
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.354
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
801
Voltage
70
Power
--
Amperage
429
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000089351: Skull [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Roger Benson, Tom Davies, Armin Schmitt
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000089351: Skull [CTImageSeries] [CT] was processed to create derived Media 000433757: Dentary [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Marc Jones
Event date
November 09, 2021
Software
Amira 6.7
Description
Dentary
Description attachment
None

Media produced by this event on MorphoSource

Media 000433757: Dentary [Mesh] [CT] (this media)