Media 000098602: Head
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000098602
Media type
Volumetric Image Series
Object element or part
head
Object represented
Object taxonomy
Scincus scincus
Side
--
Orientation
--
Short description
--
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0722 Maisano: Scincus: Scans of the head of a North African sandfish, Scincus scincus (no data, pet trade, frozen specimen; provided by Jacques Gauthier, to be accessioned into YPM) for Jessie Maisano of The University of Texas at Austin. Specimen scanned by Matthew Colbert 20 August 2002. 16bit: 1024x1024 16-bit TIFF images. II, 120 kV, 0.2 mA, no filter, air wedge, no offset, slice thickness 2 lines (= 0.0452 mm), S.O.D. 66 mm, 1000 views, 2 sample per view, inter-slice spacing 2 lines (= 0.0452 mm), field of reconstruction 15.8 mm (maximum field of view 21.648511 mm), reconstruction offset 9600, reconstruction scale 1070. Acquired with 15 slices per rotation. Reconstructed off-center: x = 1.6, y = -0.7. Total slices = 480.
Creator
--
Date created
August 20, 2002
Date uploaded
January 12, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
141 MB
Image width
832
Image height
774
Color space
BlackIsZero
Color depth
8
Compression
Uncompressed
X pixel spacing
0.015400
Y pixel spacing
0.015400
Z pixel spacing
0.045200
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
480

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Yale Peabody Museum
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
DEB-0132227, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: oUTCT provided access to these data , with data collection funded by NSF DEB-0132227 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object YPM:VZ:YPM HERR 012686 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1000
Voltage
120
Power
--
Amperage
200
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000098602: Head [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000098602: Head [CTImageSeries] [CT] (this media)