Media 000114624: Braincase
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000114624
Media type
Volumetric Image Series
Object element or part
braincase
Object represented
Object taxonomy
Apalone mutica
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive \\r\\n\\r\\nJamniczky:\\r\\nApalone: Scans of the skull and mandibles of Apalone mutica (2746) for Heather Jamniczky of the University of Calgary. Specimen scanned by Matthew Colbert 6 August 2004. Separate scan of braincase 5 August 2004.\\r\\n\\r\\nBraincase/16bitrot: 1024x1024 16-bit TIFF images. II, 180 kV, 0.133 mA, no filter, air wedge, no offset, slice thickness 2 lines (= 0.0936 mm), S.O.D. 135 mm, 1200 views, 2 samples per view, inter-slice spacing 2 lines (= 0.0.0936 mm), field of reconstruction 42 mm (maximum field of view 44.23999 mm), reconstruction offset 5400, reconstruction scale 1830. Acquired with 15 slices per rotation. Rotation correction processing done by Susan Garlock using IDL routine “DoRotationCorrection”. Total slices = 510.\\r\\n\\n\\nRelated URL: http://digimorph.org/specimens/Apalone_mutica/ Migrated MorphoSource 1 Media Group Description: Related URL: http://digimorph.org/specimens/Apalone_mutica/
Creator
--
Date created
--
Date uploaded
April 20, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
532 MB
Image width
1006
Image height
674
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.041000
Y pixel spacing
0.041000
Z pixel spacing
0.093600
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
510

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Chelonian Research Institute
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
Natural Sciences and Engineering Research Council of Canada, Alberta Ingenuity Fund, The Society of Vertebrate Palaeontology, The Chelonian Research Foundation, The Systematics Association, The Palaeontological Association, and the University of Calgary
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Heather Jamniczky provided access to these data , with data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FHSM:HERP:2746 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1200
Voltage
180
Power
--
Amperage
133
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000114624: Braincase [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000114624: Braincase [CTImageSeries] [Etc] (this media)