Media 000114668: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000114668: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000114668
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Nichollsemys baieri
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 1126\\r\\n\\r\\nJamniczky:\\r\\nNichollsemys: Scans of the fossil skull of Nichollsemys baieri, TMP 97.99.1, Bearpaw Formation, Late Campanian, Southern Alberta, Canada, for Heather Jamniczky of the University of Calgary. Specimen scanned by Matthew Colbert 17 November 2004. \\r\\n\\r\\n16bit: 512x512 16-bit TIFF images. P250D, 180 kV, 0.133 mA, no filter, empty container wedge, no offset, slice thickness = 0.25 mm, S.O.D. 686 mm, 1000 views, 1 ray averaged per view, one sample per view, inter-slice spacing = 0.25 mm, field of reconstruction 135 mm (maximum field of view 144.745 mm), reconstruction offset 7150, reconstruction scale 1850. Reconstructed with beam-hardening coefficients 0, 0.9, 0.05 Total slices = 317.\\r\\n\\n\\nRelated URL: http://digimorph.org/specimens/Nichollsemys_baieri/ Migrated MorphoSource 1 Media Group Description: Related URL: http://digimorph.org/specimens/Nichollsemys_baieri/
Creator
--
Date created
--
Date uploaded
April 21, 2020
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
98 MB
Image width
423
Image height
486
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.264000
Y pixel spacing
0.264000
Z pixel spacing
0.250000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
317
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Royal Tyrrell Museum
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
Natural Sciences and Engineering Research Council of Canada, Alberta Ingenuity Fund, The Society of Vertebrate Palaeontology, The Chelonian Research Foundation, The Systematics Association, The Palaeontological Association, and the University of Calgary
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Heather Jamniczky provided access to these dataoriginally appearing in Brinkman et al., 2006 , with data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
tmp:97.99.1
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
1000
Voltage
180
Power
--
Amperage
133
Surrounding material
empty container
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000114668: Skull [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000114668: Skull [CTImageSeries] [Etc] (this media)