Media 000343948: Cervical Vertebra
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000343948: Cervical Vertebra
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000343948
Media type
Mesh
Object element or part
Cervical Vertebra
Object represented
Object taxonomy
Nannodectes intermedius
Object organization
Side
--
Orientation
--
Short description
Houde 135
Full description
Correct chirality
Creator
--
Date created
--
Date uploaded
February 09, 2021
FILE OBJECT DETAILS Field Definitions
File name
Boyer_USNM_442229_vertebra_B.smooth.ply
File format(s)
PLY
File size
54.2 MB
Points
749969
Polygons
1499988
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
9.410, 8.753, 7.087
Centroid coordinates
5.851, 5.405, 4.337
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
1
(1 step)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian, National Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
USNM:PAL:USNM PAL442229
was imaged to create
raw
Media 000343945: Cervical Vertebra [CTImageSeries] [CT].
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Shepard, Mackenzie
Event date
February 19, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
110
Power
12.98
Amperage
118
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2000
Detector pixels size X
0.2
Detector pixels Y
2000
Detector pixels size Y
0.2
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
Media produced by this event on MorphoSource
STEP 2: IMAGE PROCESSING
Raw
Media 000343945: Cervical Vertebra [CTImageSeries] [CT]
was processed
with 1 activity
to create
derived
Media 000343948: Cervical Vertebra [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Mackenzie Shepard
Event date
February 09, 2021
Software
Avizo 8.1
Description
--
Description attachment
None
Processing Activity 1: Reconstructed Tomography to Mesh
Software
Avizo 8.1
Description
Media produced by this event on MorphoSource
Media 000343948: Cervical Vertebra [Mesh] [CT] (this media)