Media 000351514: Intermediate Phalanx
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000351514
Media type
Mesh
Object element or part
Intermediate Phalanx
Object represented
Object taxonomy
Nannodectes intermedius
Side
Unknown
Orientation
--
Short description
Correct chirality. nn2
Full description
--
Creator
--
Date created
--
Date uploaded
March 23, 2021

FILE OBJECT DETAILS Field Definitions

File name
Boyer_USNM_pal442229_claws__2.smooth.ply
File format(s)
PLY
File size
12 MB
Points
172272
Polygons
344540
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
2.088, 1.670, 2.631
Centroid coordinates
2.062, 2.858, 6.755
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian, National Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object USNM:PAL:USNM PAL442229 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
--
Event date
March 22, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
115
Power
13.5
Amperage
117
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2000
Detector pixels size X
0.2
Detector pixels Y
2000
Detector pixels size Y
0.2
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000351263: Intermediate Phalanx [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
--
Event date
March 22, 2021
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Description

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000351263: Intermediate Phalanx [CTImageSeries] [CT] was processed with 1 activity to create derived Media 000351514: Intermediate Phalanx [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Douglas Boyer, Tiye Flavien
Event date
March 23, 2021
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Description

Media produced by this event on MorphoSource

Media 000351514: Intermediate Phalanx [Mesh] [CT] (this media)