Media 000446755: Whole Specimen (No Tail)
Restricted Download
Type
CT Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000446755: Whole Specimen (No Tail)
Restricted Download
Type
CT Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS
Media ID
000446755
Media type
CT Image Series
Object element or part
Whole specimen (no tail)
Object represented
Object taxonomy
Matobosaurus maltzahni
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Edward Stanley
Date created
--
Date uploaded
June 17, 2022
FILE OBJECT DETAILS
File format(s)
image/tiff
File size
1.01 GB
Image width
943
Image height
592
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.078278
Y pixel spacing
0.078278
Z pixel spacing
0.078278
Pixel spacing units
Mm
Slice thickness
0.07827777
Number of images in set
3,481
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
California Academy of Sciences
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
CAS:HERP:263016
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
--
Software
Datos X|A
Description
MicroCT of CAS-H-263016 full specimen
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.200098
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
1200
Voltage
100kV
Power
25W
Amperage
250uA
Surrounding material
air
Xray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
Tungston (W)
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000446755: Whole Specimen (No Tail) [CTImageSeries] [CT] (this media).
Processing Details
Creator
Edward Stanley
Date processed
--
Software
Datos X|r
Description
--
Description attachment
None