Media 000167376: Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
· Public
Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000167376
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Orycteropus afer faradjius
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT Scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 1093\\r\\n\\r\\nMacrini\\r\\nOcycteropus: Scans of the skull of Orycteropus afer (AMNH 51909) for Ted Macrini of The University of Texas at Austin.. Specimen scanned in 3 sections by Matthew Colbert 8 and 11 October 2004. \\r\\n\\r\\n8bitrot: 1024x1024 8-bit TIFF images. II, 180 kV, 0.133 mA, no filter, empty container wedge, no offset, slice thickness 2 lines (= 0.202 mm), S.O.D. 295 mm, 1200 views, 2 samples per view, inter-slice spacing 2 lines (= 0.202 mm), field of reconstruction 95 mm (maximum field of view 96.67257 mm), reconstruction offset 8000, reconstruction scale 1700. Acquired with 15 slices per rotation. Spike-removal processing done on all 3 datasets by Susan Garlock based on correction of raw sinogram data using IDL routine “RK_SinoDeSpike”. Datasets separately reconstructed with default parameters, with 3rd dataset rotated -3.5 degrees during reconstruction. Rotation correction processing done by Susan Garlock using IDL routine “DoRotationCorrection” and datasets matched using Photoshop. Overlapping and extra slices deleted, then slices renumbered front to back. Turbinate bones shifted between final slices 351-352 due to movement during scanning.. Total slices = 1237.\\r\\n
Creator
--
Date created
--
Date uploaded
November 25, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
297 MB
Image width
994
Image height
738
Color space
BlackIsZero
Color depth
8
Compression
--
X pixel spacing
0.093000
Y pixel spacing
0.093000
Z pixel spacing
0.202000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,237

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
AMNH Dept of Mammalogy
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
DEB-0309369, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Ted Macrini provided access to these data , with data collection funded by NSF DEB-0309369 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object AMNH:Mammals:M-51909 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1200
Voltage
180
Power
--
Amperage
133
Surrounding material
empty container
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000167376: Skull [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000167376: Skull [CTImageSeries] [CT] (this media)