Media 000170686: Wrist
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Media 000170686: Wrist
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000170686
Media type
Volumetric Image Series
Object element or part
wrist
Object represented
Object taxonomy
Craseonycteris thonglonyai
Object organization
Side
--
Orientation
--
Short description
HRXCT scan - wrist
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0802
Simmons:
Craswrist: Scans of the wrist of Craseonycteris thonglonyai (USNM 528306; male; Thailand: Gaow Cave, Sai Yoke Waterfall, Sai Yoke District, Kanchandouri; coll. 02 Sep 1976) for Dr. Nancy Simmons of the American Museum of Natural History. Scanned by Matthew Colbert 17 January 2003. Central ray correction applied to data.
16bit: 512x512 16-bit TIFF images. II, 120 kV, 0.2 mA, no filter, air wedge, no offset, slice thickness = 1 line (= 0.010 mm), S.O.D. 29 mm, 1000 views, 6 samples per view, interslice spacing = 1 line (=0.010 mm), field of reconstruction 7.0 mm (maximum field of view 9.503 mm), reconstruction offset 14000, reconstruction scale 1400. Acquired with 27 slices per rotation. Reconstructed off-center: x = -1.0, y = -0.4. Total slices = 216.
Creator
--
Date created
January 17, 2003
Date uploaded
January 06, 2021
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
59.2 MB
Image width
460
Image height
340
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.014000
Y pixel spacing
0.014000
Z pixel spacing
0.010000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
216
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
DEB-9873663, DBI-1902242
Publisher
oUTCT PEN
Cite as
Nancy Simmons provided access to these data, with data collection funded by NSF DEB-9873663 and data upload to MorphoSource funded by DBI-1902242.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
usnm:528306
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
January 17, 2003
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
6
Projections
1000
Voltage
120
Power
--
Amperage
200
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000170686: Wrist [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000170686: Wrist [CTImageSeries] [CT] (this media)