Media 000011010: Whole Body Stl
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000011010
Media type
Mesh
Object element or part
Whole body STL
Object represented
Object taxonomy
Sphenodon punctatus
Side
--
Orientation
--
Short description
Whole body STL
Full description
Migrated MorphoSource 1 Media File Title: Whole body STL Migrated MorphoSource 1 Media Group Title: Sphenodon punctatus full body STL
Creator
--
Date created
--
Date uploaded
April 05, 2016

FILE OBJECT DETAILS Field Definitions

File name
UF14110_fullRr.stl
File format(s)
STL
File size
162 MB
Points
1596748
Polygons
3386666
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
176.671, 106.044, 178.221
Centroid coordinates
62.609, 13.712, -60.902
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
University of Florida
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Herp:14110 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1200
Voltage
150
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000011065: Whole Body Stl [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000011065: Whole Body Stl [CTImageSeries] [Etc] was processed to create derived Media 000011010: Whole Body Stl [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000011010: Whole Body Stl [Mesh] [Etc] (this media)