Media 000004486: Element Unspecified [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000004486
Media type
CTImageSeries
File format(s)
application/dicom
File size
2,076,584,136 bytes
Object element or part
--
Side
Unknown
Orientation
--
Short description
MCZ 20187 skull
Full description
Migrated MorphoSource 1 Media File Title: MCZ 20187 skull Migrated MorphoSource 1 Media Group Title: MCZ 20187 skull
Creator
--
Date created
--
Date uploaded
January 20, 2015
Image width
916
Image height
1340
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.047018
Y pixel spacing
0.047018
Z pixel spacing
0.047018
Pixel spacing units
Mm
Number of images in set
1,197

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225, Center for Nanoscale Systems (Harvard University)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Lynn Lucas and Lynn Copes provided access to these data NSF DDIG #0925793 and the Wenner Gren Foundation. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mcz:mamm:20187 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225
Device facility
Center for Nanoscale Systems (Harvard University)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
--
Projections
1050
Voltage
80
Power
0.01
Amperage
120
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000004486: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000004486: Element Unspecified [CTImageSeries] [Etc] (this media)